logo
Send Message

LED Optical and Electrical Performance Testing

LED Optical and Electrical Performance Testing
Features Gallery Product Description Request A Quote
Features
Specifications
Basic Infomation
Place of Origin: China
Brand Name: Global United Technology Services Co.,LTD
Payment & Shipping Terms
Product Description

Basic Introduction

Semiconductor light-emitting diodes (LEDs) are widely used in indicator lamps, signal lamps, instrument displays, mobile-phone backlights, automotive lighting, and many other applications. As white-LED technology continues to advance, LEDs are being adopted ever more broadly in general lighting. In the past, comprehensive national and industry standards for LED testing were lacking, so production practice could rely only on relative parameters as a basis for evaluation. This gave rise to considerable disagreement among manufacturers, users, and research institutions, and significantly hindered the development of China's LED industry.

Photometric Measurement

Luminous Flux

Method 1 — Integrating-sphere spectroradiometer

Reference standards:

  • CIE 84:1989, Measurement of Luminous Flux
  • IESNA LM-79-08, Electrical and Photometric Measurements of Solid-State Lighting Products

Method 2 — Goniophotometer

Reference standards:

  • CIE 84:1989, Measurement of Luminous Flux
  • IESNA LM-79-08, Electrical and Photometric Measurements of Solid-State Lighting Products

Test items:

 
       

Beam angle
 
Luminous efficacy Luminous flux Zonal luminous flux

Spectral power distribution
 
Color difference Peak wavelength Lumen maintenance

Color rendering index
 
Chromaticity coordinates Color tolerance  

Luminous Intensity Distribution (Light Distribution Curve)

Method — Goniophotometer
 

Reference standards:

 

Standard

Title

IESNA LM-79-08
Electrical and Photometric Measurements of Solid-State Lighting Products
 
CIE 121:1998
The Photometry and Goniophotometry of Luminaires
 
CIE 043:1979
Photometry of Floodlights
 
GB/T 9468
General Requirements for the Goniophotometric Measurement of Luminaires
 
GB/T 7002:2008
Photometric Testing of Floodlighting Luminaires
 


Test items:

 
       
Luminaire efficacy Beam angle
Luminous intensity distribution of luminaire
 
Luminance limitation curve
Indoor luminaire planning curves
Iso-luminous-intensity distribution curves
 
Total luminous flux Zonal luminous flux
Planar iso-illuminance curves Circular iso-illuminance curves Ballast lumen factor (BLF)
Rectangular iso-luminous-intensity curves
 
 

Test Methods

An LED is a unipolar PN-junction diode made of inorganic semiconductor materials. The relationship between its voltage and current is known as the volt–ampere (V–I) characteristic. The electrical parameters of an LED include forward current, forward voltage, reverse current, and reverse voltage; an LED must be driven at an appropriate current and voltage to operate properly (see Figure 1). Electrical characterization yields the maximum permissible forward voltage and forward current, the reverse voltage and reverse current, and the optimum operating electrical power of the device.
 

Electrical characteristics are generally measured with voltmeters and ammeters while the LED is powered by a corresponding constant-current / constant-voltage source.

Optical Characteristic Testing

As with other light sources, optical characterization of LEDs mainly covers luminous flux, luminous efficacy, radiant flux, radiant efficiency, luminous intensity, luminous intensity distribution, and spectral parameters.

Luminous Flux and Luminous Efficacy

There are two methods for measuring luminous flux: the integrating-sphere method and the goniophotometric method. The goniophotometric method is the most accurate, but because it is time-consuming, luminous flux is generally measured with an integrating sphere. Two configurations are used in existing integrating-sphere LED measurements: one places the LED under test at the center of the sphere, and the other mounts it on the sphere wall.

Because self-absorption of light by the source itself affects the result in integrating-sphere measurements, an auxiliary lamp is often introduced. Once the luminous flux has been obtained, the luminous efficacy of the LED can be determined in conjunction with electrical parameter measurements. Radiant flux and radiant efficiency are measured in a manner analogous to luminous flux and luminous efficacy.

Luminous Intensity and Luminous Intensity Distribution

For a point source whose luminous intensity is uniform in all directions, the measured result does not change with measurement distance or with the aperture of the detector used. LEDs, however, have non-uniform intensity distributions, so their measured values vary with test distance and detector aperture. CIE 127 therefore specifies two recommended measurement conditions, allowing all LEDs to be tested and evaluated for luminous intensity under identical conditions (see Figure 5). These CIE 127 recommended conditions are now adopted by LED manufacturers and testing institutions worldwide.

Spectral Parameters

The spectral characteristics of an LED mainly include peak emission wavelength, spectral bandwidth, and spectral power distribution. A single-color LED exhibits one spectral peak and is characterized by its peak wavelength and bandwidth, whereas the spectrum of a white LED is a composite of several monochromatic components. The spectral characteristics of every LED — including the spectral power distribution of white LEDs — can be described by its spectral power distribution (SPD), from which the colorimetric parameters can in turn be calculated.

Measuring the SPD requires spectrally resolving the mixed light so that each wavelength component can be measured separately; this dispersion is generally achieved with prisms or gratings.
 

Our Advantages

  • A team of qualified, experienced technical experts providing professional consulting and services.
  • Advanced laboratory equipment ensuring accurate and reliable test data.
  • As a third-party testing and certification organization trusted by clients worldwide, we stand as a credential of your quality.



Global United Technology Services Co., Ltd. owns Internationally recognized CNAS (L5775) laboratory qualification, US FCC NVLAP qualification, domestic CMA qualification for inspection and testing in, capable of issuing internationally mutually recognized test reports, as well as authorized qualifications from major institutions such as UK's ITS, Germany's TUV, and Belgium's Eurof; focusing on the core testing fields of EMC, electrical safety, wireless RF, and chemical testing certification agency for export compliance, providing a one-stop service of "testing rectification technical training", making us your ideal partner!

Email:vicky.mo@gtstest.com
Whatsapp: +18025848511
WeChat:  18025848511

 

Recommended Products
Get in touch with us
Contact Person : Venus Chen
Tel : 0086 137 9823 6128
Characters Remaining(20/3000)