Morocco regulates imported industrial products under Law No. 24-09 on the Safety of Products and Services. With the exception of a limited number of product categories subject to destination inspection at the Moroccan border, all other regulated industrial products must, in principle, undergo a pre-shipment conformity assessment in the country of export and obtain a CoC (Certificate of Conformity) before import clearance.
1. Recognized Bodies and the Certification Route for This Shipment
Conformity assessment bodies currently recognized by Morocco include SGS, Bureau Veritas, Intertek, and TÜV Rheinland, among others. The CoC is a key document for import clearance of the regulated goods concerned.
Product details for this shipment:
|
Item
|
Detail
|
| Product |
LED Panel Light
|
| Brand / Manufacturer / Model / Quantity |
To be provided by the client
|
| Country of origin |
China
|
| Certification route |
Route A
|
Route A generally applies to first-time or infrequent exporters, or to suppliers that have not yet completed product registration. The assessment typically covers document review, test report review, and — depending on the outcome of a risk analysis — an on-site inspection or sample testing.
2. Moroccan Technical Regulations Applicable to LED Panel Lights
LED panel lights are mainly governed by two Moroccan ministerial orders (arrêtés):
- Arrêté No. 2573-14: safety requirements for low-voltage electrical equipment
- Arrêté No. 2574-14: electromagnetic compatibility (EMC) requirements
3. Selecting the Right Standards: Installation Method First
The official Moroccan list of mandatory standards explicitly covers general luminaire safety, fixed luminaires, recessed luminaires, and road lighting luminaires as separate categories.
⚠️ Important note: NM EN 60598-2-3, as listed in the client's documents, applies primarily to road and street lighting luminaires. If RD.PNL is an indoor ceiling-recessed panel light, the more common
combination is:
NM EN 60598-1 + recessed luminaire standard NM 06.7.082
If the product is a surface-mounted fixed panel light, the likely combination is:
NM EN 60598-1 + fixed general-purpose luminaire standard NM 06.7.081
The applicable standards therefore cannot be determined from the English product name "LED Panel Light" alone. Before applying, confirm whether the product is recessed, surface-mounted, or intended for road lighting, and submit structural photos, the installation manual, and the specification sheet so that the conformity assessment body can finalize the scope of standards.
Also note that Moroccan authorities explicitly require the technical file to reference NM standards. A CE certificate alone, or a test report listing only EU EN standards, does not automatically satisfy Moroccan requirements. Where an NM standard is identical to its EN counterpart, prepare an NM / EN standards correlation table in advance.
4. Recommended Test Reports
1. Luminaire safety test report
- Structural safety
- Protection against electric shock
- Earthing continuity
- Insulation resistance and dielectric strength
- Temperature rise
- Resistance to heat and fire
- IP (dust and water ingress) rating
- Mechanical strength
- Durability of markings
2. LED driver / power supply safety report
- Input and output parameters
- Insulation and creepage distances
- Abnormal operation
- Short-circuit and overload protection
- Temperature rise and withstand voltage
3. EMC test report
- Conducted and radiated disturbances
- Harmonic currents, voltage fluctuations and flicker
- Immunity to ESD, surges, electrical fast transients, and radiated RF
Reports should preferably be issued by laboratories accredited to ISO/IEC 17025 with a scope covering the relevant standards. SGS's Morocco scheme documentation likewise cites reports from ISO/IEC 17025-accredited laboratories under the ILAC Mutual Recognition Arrangement as a primary basis for acceptance.
Consistency requirement: the tested model, product photos, brand, wattage, driver model, and critical components must fully cover the goods actually being shipped.
5. Markings on the Product and Nameplate
The luminaire body or nameplate should include at minimum:
- Product name, brand, and model
- Rated voltage (e.g. 220–240V~), rated frequency (e.g. 50/60Hz), rated power (e.g. 36W)
- Protection class: Class I / Class II / Class III
- IP rating
- Manufacturer name or recognizable trademark
- Batch number or date of manufacture
- Country of origin: Made in China
- Required safety warnings
- CMIM conformity mark (Cم)
The CMIM mark must be legible, visible, and durable, with the vertical height of the letter "C" in principle no less than 6 mm. It should normally be applied to the product itself; only where the nature or size of the product genuinely does not allow this may it be placed on the packaging and accompanying documents instead.
6. Instructions and Packaging Requirements
Language: user-facing information must at minimum be provided in Arabic. The technical file may be in Arabic, French, or English, but warnings, installation instructions, and consumer information must be available in Arabic.
Retail box / sales packaging — recommended markings
- Product name in Arabic, French, or English
- Brand, model, and product image
- Rated voltage, frequency, and power
- Colour temperature (e.g. 3000K / 4000K / 6500K) and luminous flux
- IP rating, installation method, dimensions
- Manufacturer name and address
- Moroccan importer name and address
- Made in China, date of manufacture or batch number
- CMIM mark
- Arabic installation instructions and safety warnings
- Applicable cautions (e.g. "For indoor use only", "Non-dimmable")
- Barcode or product traceability code
Outer carton — recommended markings
- LED PANEL LIGHT
- Brand, model, wattage, colour temperature
- Quantity per carton, net / gross weight, carton dimensions, carton number
- Batch number or date of manufacture, Made in China
- Manufacturer or exporter details, Moroccan importer details
- Handling pictograms: Keep Dry, This Side Up, Fragile
The brand, model, and wattage must be fully consistent across the nameplate, retail box, instruction manual, test reports, commercial invoice, and packing list.
7. Document Checklist for a Route A Application
- CoC application form
- Proforma invoice or commercial invoice; packing list
- Product specification sheet; product photos; nameplate photo
- Retail box artwork and outer carton shipping marks
- Arabic (or Arabic / French) instruction manual
- Luminaire safety test report; LED driver test report; EMC test report
- Critical component list; circuit diagram; structural drawings
- Moroccan Declaration of Conformity
- NM-to-EN/IEC standards correlation table
- Certificate of Origin; ISO 9001 certificate (if available)
- Draft Bill of Lading or shipping documents
- Moroccan importer details
The Moroccan technical file should additionally contain a product description, design and manufacturing drawings, a parts and materials list, a list of applicable standards, risk-control notes, design calculations, and internal inspection results. Such documentation should in principle be retained for 10 years.
8. What On-Site Inspection Covers
Moroccan authorities describe import inspection as four stages: document review, physical inspection, sampling, and market entry. Physical verification covers quantity, brand, country of origin, conformity marking, packaging, labelling, and the condition of the goods. Inspectors typically focus on:
- Whether actual quantities match the invoice and packing list
- Whether brand, model, and wattage match the test reports
- Whether appearance and construction match the submitted documents
- Whether the nameplate is securely fixed, legible, and durable, and whether the CMIM mark (Cم) is correctly applied
- Whether rated voltage, frequency, power, and IP rating are marked
- Whether retail boxes and outer cartons carry country-of-origin information
- Whether Arabic instructions and warnings are present
- Whether information is consistent across product, retail box, outer carton, and manual
- Whether packaging is intact, with no damage, moisture ingress, or mixed loads
- Whether the LED driver, power cord, terminals, and other critical components match the reports
- Power-on and basic functional checks on randomly selected units
- Samples sent to a laboratory for testing where necessary
9. Common Non-Conformities
- CE marking only, with no Moroccan CMIM mark
- Test reports not referencing NM standards, or no correlation table provided
- Model in the test report differing from the shipped model
- The panel light's intended use not matching the selected IEC/EN 60598-2 part
- LED driver model differing from the one in the report
- Missing Arabic warnings or instructions
- Nameplate missing voltage, frequency, power, or manufacturer details
- Model inconsistencies across retail box, outer carton, and invoice
- CoC application initiated only after container stuffing or shipment
- Goods not fully produced, or packaging quantities incomplete, at the time of inspection
- Use of a power supply, PCB, or critical component not covered by the test report
We recommend running a self-check against this list after production is complete but before container stuffing, then initiating the application and inspection arrangements. This significantly reduces the risk of document supplements, re-inspection, and port detention.
Editorial Notes (on the Chinese revision)
- Terminology standardized: "Coc" → "CoC"; inconsistent use of
Cم / CMIM was aligned by introducing "CMIM conformity mark (Cم)" at first mention and using "CMIM" thereafter; "签证机构" was replaced with "conformity assessment body".
- Structure tightened: shipment details converted into a table; the "four inspection stages" moved to the opening of Section 8 as context; three overlapping consistency reminders consolidated into bold call-outs at the end of the relevant sections, with no check item removed.
- All regulation and standard numbers, sub-items, and figures retained — including the 6 mm mark height and the 10-year retention period. Only phrasing, rhythm, and heading hierarchy were adjusted; no technical conclusion was changed.
Global United Technology Services Co., Ltd. owns Internationally recognized CNAS (L5775) laboratory qualification, US FCC NVLAP qualification, domestic CMA qualification for inspection and testing in, capable of issuing internationally mutually recognized test reports, as well as authorized qualifications from major institutions such as UK's ITS, Germany's TUV, and Belgium's Eurof; focusing on the core testing fields of EMC, electrical safety, wireless RF, and chemical testing certification agency for export compliance, providing a one-stop service of "testing rectification technical training", making us your ideal partner!